EXTERIOR DESIGN
FIRE PROTECTION
ELEVATORS
SECURITY
TELECOMMUNICATION
ALL
Facade comprises of
curtain wall & strip glazing with high performance glass units and a
combination of Textured Paint, Stone and ACP cladding; full length
floor-to-ceiling glazing at ground level
AIR-CONDITIONING
Centralized cooling
system based on energy efficient water cooled chillers equipped with BMS
controls. One chiller on variable frequency drive for efficient operation at
partial loads; Chilled water piping provided upto each floor level.
ENTRANCE LOBBY
Expansive double height
entrance lobby features stone and wood veneer panels on the backdrop wall and
stone flooring with accent bands & steel inserts; Fully equipped concierge
desk.
VENTILATION & EXHAUST
Ducted ventilation
systems/smoke extraction facility in basements
SIGNAGE
External signage
integrated with landscape elements and internal signage integrated with the
lobby design
CONSTRUCTION
Reinforced Cement
Concrete frame structure with column and flat slab construction
POWER
Primary source of power
is from the Grid; Secondary power through captive generation with heat recovery
SECONDARY POWER
100% fully automatic
diesel generator for lighting, power & Air-conditioning requirements.
Provision made for PLC based auto sharing and auto load balancing AMF panel system
ROOF
Waterproofed RCC roof
with inverted rigid insulation
FIRE PROTECTION
Automatic fire
sprinklers integrated with a fire alarm system installed in all areas;
Centrally located main fire alarm control panel provided; Equipped with hand
held and yard hydrants; UPS backed emergency light fixtures provided at all
means of egress
ELEVATORS
Computerized high-speed
traction elevators serving all levels. Separate parking elevators. Access
control at main elevator lobby.
SECURITY
Video surveillance at
all strategic locations covering the site exterior, basements and all critical
common areas; Security personnel located at critical entry and exit points.
TELECOMMUNICATION
Tag blocks provided at